Promat s range of fire protection steel coating products ensure protection against fire to a buildings structure and services such as kitchen exhaust ventilation duct work and air plenums.
Fire protection coating for steel.
Boards and blanket fire protection system.
Architectural fire protection for exposed structural steel in interior and exterior applications hilti fire finish 120 cfp sp wb is a high performance water based intumescent fire resistive material or ifrm for architecturally exposed structural steel in interior and exterior applications with approved top coats.
Intumescent coating steel structure fire protection system.
Provides intumescent fire protection that exceeds many astm e119 listing standards.
All fireshield fire coating systems fire tested and assessed around the globe for use in new zealand.
Fire protection solutions limited were involved in coating the steel with it s clean white finish over an 8 month period last year.
Sprayed cementitious or gypsum based coatings.
Fireshield timber and steel systems are compliant with the new zealand building code.
Fire protection coatings reactive fire protection systems from the specialist specialist for reactive fire protection systems.
Passive fire protection materials insulate steel structures from the effects of the high temperatures that may be generated in fire.
In addition to the aforementioned systems there are also some other systems such as cladding with fire.
This type of fire protection system as shown in figure 2 is widely used due to several reasons such as it is clean cost effective water resistant and can be applied to non painted steel members.
3 data for great britain tata steel steel construction fire protection 2013.
Structural steel is the most commonly protected material but protection can include other materials such as sheet metal sheetrock composite panels and interior woods.
Cafco is the market leader for steel and concrete protection and trusted by applicators worldwide.
70 while cladding with boards are used by approx.
They can be divided into two types non reactive of which the most common types are boards and sprays and reactive of which thin film intumescent coatings are the most common example.
Thin film intumescent coatings can be either on site or off site applied.
All clear and pigmented timber systems offer up to group 1 surface finishes fireshield can only be installed by registered.
25 and fire stopping sprays by approx.
Fire protection is accomplished through a combination of active and passive fire protection methods.
A majority of steel structures use intumescent paints approx.